{"id":7482,"date":"2022-10-09T18:16:33","date_gmt":"2022-10-09T07:16:33","guid":{"rendered":"https:\/\/ticapacific.au\/?post_type=product&p=7482"},"modified":"2022-10-10T12:13:25","modified_gmt":"2022-10-10T01:13:25","slug":"tims-axa-5","status":"publish","type":"product","link":"https:\/\/ticapacific.au\/products\/vrf-inverter-split-system\/tims-axa-5\/","title":{"rendered":"TIMS-AXA"},"content":{"rendered":"\t\t
TIMS-AXA<\/strong><\/p> 2 x Modular Outdoor unit, 380-\/-720<\/p> Cooling Capacity: 106 - 204 kW<\/b><\/p> Heating Capacity: 119 - 225 kW<\/strong><\/p> Compressor: Scroll R410A<\/strong><\/p> <\/div>\r\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t \r\n When the ambient temperature reaches the limit condition, the heat exchange capacity of the outdoor unit declines, and the air return\nvolume of the compressor is reduced, accompanied by problems in compressor suction and discharge protection. The TICA TIMS VRF\nunit adopts the high efficiency EVI system and cooperates with TICA's new inverter control and refrigerant system. In the unit, refrigerant\nis added through the air jetting port to increase the displacement, so as to broaden the cooling and heating ranges of the unit, enhance the\noverall capacity by 20%. In addition, the added refrigerant is injected into the pressure chamber of compressor to reduce the compression\nratio and power consumption of the compressor, and improve the COP value by 10% <\/p>\r\n <\/dd>\r\n \r\n The ODU fan motor adopts the DC inverter motor that features an 45% increase in efficiency\nand substantial decrease in power consumption. Stepless speed control of the fan based on\nenvironmental conditions and air conditioner load, together with the stepless inverter technology of\ncompressor, can achieve highly precise control for more stable and reliable operation. <\/p>\r\n <\/dd>\r\n \r\n TICA inverter VRF ODU adopts the efficient heat exchanger to achieve 12\u2103 stage-1 super-cooling, and 20\u2103 stage-2 <\/p>\r\n <\/dd>\r\n \r\n The ODU heat exchanger adopts the \u03c6 7.0 internal thread efficient heat-conducting copper tube and new aluminum fin, as\n <\/p>\r\n <\/dd>\r\n \r\n The specially designed TWO-TO-ONE refrigerant loop\ncan effectively increase the amount of liquid refrigerant.\nAs a result, less resistance to refrigerant flow can\nincrease the comprehensive coefficient of heat transfer\nand further optimize the system. <\/p>\r\n <\/dd>\r\n <\/dl>\r\n <\/div>\r\n <\/div>\r\n<\/section>\r\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t Submit the product inquiry form with your questions to get a PDF product brochure with technical specifications.<\/p>\r\n <\/div>\r\n \r\n<\/div>\r\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t <\/p> \r\n
<\/ul><\/div>\n